IPC - 708.3.2 Building sewers. The clean-out fitting can take a number of different appearances, but most typically it is a 3-inch, 4-inch, or 6-inch … The consequences on not doing so can include multiple backed-up sinks and toilet waste draining into the tub instead of leaving the house. "P” trap connections with slip joints or ground joint connections, or stack cleanouts that are not more than one pipe diameter smaller than the drain served, shall be permitted. It has finely machined threads to help prevent installation problems. For a long time, the plumbing codes have had requirements for the location and size of openings in the drainage pipes to allow drain cleaning machines to have access to the drainage piping. Where it is necessary to conceal a cleanout or to terminate a cleanout in an area subject to vehicular traffic, the covering plate, access door or cleanout shall be of an approved type designed and installed for this purpose. Cleanouts and drains should be routed to avoid being over food preparation areas, hospital operating rooms, computer rooms or other critical areas. Photo courtesy Galow Homes. Use a pipe wrench to loosen the cap on your main line drain pipe before you open it entirely. your three inch flexible hose from the RV should fit. And if you call a plumber for this rush job, you'll likely end up with a hefty bill. Cleanouts located under cover plates shall be so installed as to provide the clearances and accessibility required by this section. Plugs shall have raised square heads or approved countersunk rectangular slots. Cleanout plugs shall be brass or plastic, or other approved materials. Brass cleanout plugs shall be utilized with metallic drain, waste and vent piping only and shall conform to ASTM A 74, ASME A112.3.1 or ASME A112.36.2M. Every cleanout shall be installed to open to allow cleaning in the direction of the flow of the drainage pipe or at right angles thereto. Manholes and manhole covers shall be of an approved type. 40: 1-1/2" $6.94 : Raised Head Southern Code Brass Cleanout Plug for DWV The Jones Stephens Brass Southern Code Clean-Out The Jones Stephens Brass Southern Code Clean-Out Plug with Raised Head features a precise pattern for an accurate fit. "Tree and shrub roots in your yard are on the prowl for water and nutrients. A cleanout is a 3- or 4-inch pipe fitted with a … You'll be able to see when it happens because the water level in the drain pipe will begin to gradually decrease and then drain out entirely. Add to Cart. x 4 in. It has hub connections. The Annoying House Sound You Can Eliminate, How to Unclog a Garbage Disposal Without Calling a Plumber, How the Rollout of COVID-19 Vaccines Could Help—and Hurt—the U.S. Housing Market, ‘CBS Sunday Morning’ Host Jane Pauley Sells Hudson River Retreat for $6.3M, Lessons From Listing Photos: Why This Modest Home Sold in 5 Days and Grew In Value, 5 Things You Didn’t Know a VA Loan Could Do for You, Tom Brady and Gisele Bundchen Finally Sell Their Massachusetts Mansion. The exterior sewer connection pipe was six-inch pipe. This replaced a broken plug that must have been run over by the previous owner with a lawn mower. IPC - 708.7 Minimum size. ... Capped off my broken turd pipe clean out. Cast-iron cleanout sizing shall be in accordance with referenced standards in Table 702.4, ASTM A 74 for hub and spigot fittings or ASTM A 888 or CISPI 301 for hubless fittings. Save water safely, my friends. Manholes serving a building drain shall have secured gas-tight covers and shall be located in accordance with Section 708.3.2. Can be solvent welded inside 4 in. Sewer Cleanout - Extending Height; Author: Robert Meyer (CA) I have a sewer clean out that ground water tends to come up to. When you're done, place the cap back on your drain pipe and use the pipe wrench to tighten it back up again. Once the clog has been removed, spray the hose down your drain pipe at full blast. EACH. Step 6: Slowly pull the auger back out of the pipe. Requires a cleanout plug or flush plug. He has served as chairman of the International Residential Plumbing & Mechanical Code Committee. Cleanout plugs with borosilicate glass systems shall be of borosilicate glass. UPC - 707.2 Each cleanout fitting and each cleanout plug or cap shall be of an approved type. IPC - 708.2 Cleanout plugs. Step 5: Hose down the pipe and auger cable. UPC - 707.11 Cleanouts shall be provided for pressure drainage systems as classified under Section 710.7. They are used in gravity-fed waste elimination systems and are for Non-Pressure systems where Proudly made in the USA . Visit www.Plumb-TechLLC.com, email Ron@Plumb-TechLLC.com or phone 734/755-1908. Note: If you do not know your pipe size, measure the OD of your existing cleanout plug or the ID of your cleanout fitting and match to the value listed. "Improperly installed sewer pipes or pipes that may have shifted over time due to changes in your yard are also more prone to clogs.". PVC Sewer and Drain Pipe MPT Cleanout Plug: 1-1/2 in. The Sewer Cleanout and its Cap Cover. 3-in x 4-in Dia PVC Sewer Drain Adapter Coupling. IPC - 708.3.6 Manholes. All horizontal drains shall be provided with cleanouts located not more than 100 feet (30 480 mm) apart. If cleanouts are over sensitive areas, and if there is no way to avoid having pipes in the ceiling, consider using drain pans under the drains. Removing a Stuck Sewer Cleanout Cap. The NIBCO 4 in. You can read more of her work on her website: https://www.tmrealestatewriter.com/, This site is protected by reCAPTCHA and the, Sorry, we were unable to share this article. $9.63. IPC - 708.3 Where required. When designing sanitary or storm drainage systems, it is important for the design professional to think about how the drainage system will be maintained. The cleanout at the junction of the building drain and building sewer shall not be required if the cleanout on a 3-inch (76 mm) or larger diameter soil stack is located within a developed length of 10 feet (3048 mm) of the building drain and building sewer connection. Don't Neglect These 6 Maintenance Tasks—or Else, Debunked! UPC - 707.8 Each cleanout, unless installed under an approved cover plate, shall be above grade, readily accessible, and so located as to serve the purpose for which it is intended. Cleanouts shall be the same nominal size as the pipe they serve up to 4 inches (102 mm). IPC - 708.3.3 Changes of direction. No under-floor cleanout shall be located exceeding twenty (20) feet (6,096 mm) from an access door, trap door, or crawl hole. Cleanout plugs shall not be covered with cement, plaster or any other permanent finish material. So when do you throw in the wet towel and call in the professionals? Camco Sewer Cleanout Plug Wrench Universal 4" 4.0 out of 5 stars 1. However, if you're game to do a little DIY home maintenance, you can take care of it for a fraction of the cost. Solvent welds into fitting hub to provide access to piping for sewer lines, septic tank and seepage systems. Looking for OATEY 4 in — Cleanout Plug, Brass (3NWC9)? Quickly open the cap and step out of the way. Cleanouts on 8-inch (203 mm) and larger pipes shall be provided with a clearance of not less than 36 inches (914 mm) for rodding. Nasty! When drains serving floors above grade require cleanouts, consider the spaces on the floor below where the drainlines change direction. THe plumber had to dig about 4 feet down, and he had to cut out about 3 feet of galvanized steel. IPC - 708.3.4 Base of stack. Click Follow Search to get alerts on new listings. Cancel $ PROFLO® 7-1/4 in. Each cleanout for galvanized wrought-iron, galvanized steel, copper, or brass pipe shall consist of a brass plug as specified in Table 7-6, or a standard weight brass cap, or an approved ABS or PVC plastic plug, or an approved stainless steel cleanout or plug. UPC - 707.5 Each cleanout shall be installed so that it opens to allow cleaning in the direction of flow of the soil or waste or at right angles thereto and, except in the case of wye branch and end-of-line cleanouts, shall be installed vertically above the flow line of the pipe. 2012 International Plumbing Code - Cleanout requirements: IPC - 708.1 Scope. For pipes larger than 4 inches (102 mm) nominal size, the size of the cleanout shall be not less than 4 inches (102 mm). Oatey 33403 Plastic Plug (with Galvanized screw and wing nut), 4-Inch Cleanouts in under-floor piping shall be extended to or above the finished floor or shall be extended outside the building when there is less than eighteen (18) inches (457 mm) vertical overall, allowing for obstructions such as ducts, beams, and piping, and thirty (30) inches of (762 mm) horizontal clearance from the means of access to such cleanout. Access shall be provided to all cleanouts. Shop undefined 4-in Dia 90-Degree PVC Sewer Drain Sewer Tee in the Outdoor Drainage Accessories department at Lowe's.com. Item #55811 Model #02238L. Here are the various ways to locate a sewer drain cleanout. Requires a cleanout plug or flush plug. Recessed. Cleanouts shall be permitted to be omitted on a horizontal drain line less than five (5) feet (1,524 mm) in length unless such line is serving sinks or urinals. This section shall govern the size, location, installation and maintenance of drainage pipe cleanouts. Cleanout plug wrench for 3 and 4 inch sewer caps - clean out sewer plug removal tool. BOILER 2021 – ABMA Boiler Technology Conference & Expo. UPC - 707.13 When a hubless blind plug is used for a required cleanout, the complete coupling and plug shall be accessible for removal or replacement. EACH. Zurn CO-PV3 PVC Finished Area Adjustable Cleanout with Nickel Bronze Cover, 4" Pipe Size, 5" Di… Get Pricing and Availability. An approved two-way cleanout is allowed to be used at this location to serve as a required cleanout for both the building drain and building sewer. One thing to keep in mind is that clean-out caps can leak just like any other plumbing fitting. This cleanout fitting features a SPT x FPT connection. So pull on your work gloves and take a look at this guide on how to fix a sewer clog without having to dip into your home repair emergency fund. x 4 in. Get quick and easy access to your home value, neighborhood activity and financial possibilites. 1 - 24 of 409 results for "4" sewer" Page 1 of 18 6 in. How to clean out a main sewer line clog. Each adapter includes a flush clean-out plug with brass insert, especially useful for applications that require a flush-finish such as on walls or sidewalks. Ron George is president of Plumb-Tech Design and Consulting Services LLC. Each auger, or plumbing snake, is different, so be sure to follow the instructions that come with the tool for best results. IPC - 708.4 Concealed piping. UPC - 707.14 Cleanouts for trap arms shall be installed in accordance with Section 1002.3. Cleanout openings shall not be utilized for the installation of new fixtures, except where approved and where another cleanout of equal access and capacity is provided. UPC - 1002.3 A trap arm shall be permitted to change direction without the use of a cleanout when such change of direction does not exceed 90 degrees (1.6 rad). Add to Cart. Cleanouts shall be installed at each change of direction greater than 45 degrees (0.79 rad) in the building sewer, building drain and horizontal waste or soil lines. Item #23330. Doing so will simultaneously remove any lingering debris that is stuck in the pipe and clean off the auger. The Oatey 4 in. Multi-Fittings Corporation Trench Tough Plus™ 4 in. PVC Sewer Popper Cleanout and Relief Valve: Price $ The in-building drains (not visible here) were 4-inch ABS pipe. A cleanout shall be provided at the base of each waste or soil stack. In some cases, drains can be offset to rise up in walls to avoid cleanout covers in high traffic areas. Cleanout Plug 4 inch FPT A cleanout plug fits into a cleanout adapter to seal the fitting once a blockage in the sewer line has been removed. UPC - 707.12 Countersunk cleanout plugs shall be installed where raised heads cause a hazard. Gravity prevents it from going back into your house; sewer lines slope gradually downhill throughout their length. Subscribe to our newsletters & stay updated, Watts to Host Webinar: "Corrosive Waste Drainage Systems for Plenum Spaces", The International Code Council Ensures Building Codes Meet Safety Requirements, Watts "Ultra-Hygienic Drainage Solutions" Webinar, DDI System "Key Strategies for Solving the eCommerce & ERP Disconnect" Webinar, Emergency fixtures and emergency fixture mixing valve standards, Part 1, Saniflo USA Announces Restructuring of National Sales Team, Operating Commercial Buildings with Confidence in the Age of COVID. By continuing to browse the site you are agreeing to our use of cookies in accordance with our Cookie Policy. Fits Pipe Size Cleanout Plug Size (included) Black ABS Price & Quantity White PVC Price & Quantity; Inside 2" Sch. 3-inch. IPC - 708.6 Prohibited installation. This tee is designed to connect three pipes in underground non-pressurized plumbing applications. There could still be smaller pockets elsewhere in the pipe, which may cause additional problems down the road. PROFLO® 7-1/4 in. UPC - 707.3 Cleanouts shall be designed to be gas and water-tight. 07 $12.99 $12.99 5.0 out of 5 stars 1. Step 3: Feed the auger cable into the drain pipe. Where more than one change of direction occurs in a run of piping, only one cleanout shall be required for each 40 feet (12 192 mm) of developed length of the drainage piping. IPC - 708.3.5 Building drain and building sewer junction. Raised. Plastic Dome Cleanout Cover Polished Chrome. Step 1: Loosen the cap on the drain pipe. Step 2: Open the cap and let the buildup drain out. Occasionally, sewer backups can be caused by problems that are more serious than your run-of-the-mill clog. Add to Cart. PVC fittings are for drain, waste and vent purposes. Access to drainage cleanouts is becoming more important, as various states have proposed water conservation legislation that will phase in over the next few years and that mandates lower flow rates for various plumbing fixtures. Examine the likely locations –The first way involves looking around in the house and the compound in places where you would expect the facility to be installed. Plumbers install sewer cleanout fittings so you can get inside sewer pipes and remove blockages. You'll know when you've hit it because the cable will get progressively harder to move through the pipe. 4-1/2 in. UPC - 707.6 Each cleanout extension shall be considered as drainage piping and each 90 degree (1.6 rad) cleanout extension shall be extended from a wye type fitting or other approved fitting of equivalent sweep. Solvent weld. UPC - 707.4 Each horizontal drainage pipe shall be provided with a cleanout at its upper terminal, and each run of piping, that is more than one-hundred (100) feet (30,480 mm) in total developed length, shall be provided with a cleanout for each one-hundred (100) feet (30,480 mm), or fraction thereof, in length of such piping. Clay to Cast Iron PVC Flexible Coupling with Stainless Steel Clamps: 3 in. Cleanouts with plate-style access covers shall be fitted with corrosion-resisting fasteners. UPC - 707.7 Each cleanout for an interceptor shall be outside of such interceptor. There shall be a cleanout near the junction of the building drain and the building sewer. Read more. Part #: PFDAC7W. Facets of Austin opens its renovated showroom designed to showcase only the products it sells with no distractions. A main sewer line clog might not seem to present an immediate threat to your home (like, oh, a fire), but it's an issue that should be addressed as quickly as possible. Those are the times when you want to be able to rest easy knowing your system will receive the correct diagnosis and treatment. Answered by Bearsy: I had a plumber install a two way cleanout yesterday (6/16/2017). Generally, a distance of about three feet from a cleanout to any obstruction or wall is required. With this design, it should present no challenge when I go to mow the yard in the spring! I want to extend the height of the 4 wide inch abs sewer line maybe five or 6 inches. Cleanouts on 6-inch (153 mm) and smaller pipes shall be provided with a clearance of not less than 18 inches (457 mm) for rodding. Countersunk heads shall be installed where raised heads are a trip hazard. Any waste that the clog has caused to build up will come spilling out of the main line drain. As water flows are reduced, and as waste is diverted away from drainage systems for graywater systems, drainline blockages will increase, and the need for cleanouts will increase. Grainger's got your back. Cleanout Adapter 4 inch SpxFPT The cleanout adapter fits into the hub of a PVC-BDS sewer fitting to allow for clearance of blockages in the sewer line. 4-inch. Augering the main sewer line is fairly easy if there is an accessible clean-out; it's much harder (and more expensive) if the plumber has trouble getting at the sewer line. That said, don't stop running the machine as soon as the clog disappears. It looks like Cookies are disabled in your browser. Drains should be routed far enough away from walls and obstructions that the drain cleaning machine can gain access if needed. DANCO PlugAll Mechanical Test, Seal & Cleanout Pipe Plug | For Drains & Clean-outs | Fits 1-1/2 inch and 2 inch pipes | DWV Testing (10839),Red 4.2 out of 5 stars 205 $9.07 $ 9 . Cleanouts on concealed piping or piping under a floor slab or in a crawl space of less than 24 inches (610 mm) in height or a plenum shall be extended through and terminate flush with the finished wall, floor or ground surface or shall be extended to the outside of the building. Building sewers shall be provided with cleanouts located not more than 100 feet (30 480 mm) apart, measured from the upstream entrance of the cleanout. For Pipe Size: Thread Type: Cleanout Plug OD/Fitting ID : Each : Each: Brass. UPC - 707.9 Each cleanout in piping two (2) inches (50 mm) or less in size shall be so installed that there is a clearance of not less than twelve (12) inches (305 mm) in front of the cleanout. If the drains must be in the ceiling over sensitive areas, remember that, if there is a blockage, when a plumber removes the cleanout plug, sewage can drain out of the backed up drain and cause damage and possibly the spread of disease and other pathogens to areas below. The International Code Council (ICC) develops and maintains the International Plumbing Code (IPC), and the International Association of Plumbing and Mechanical Officials (IAPMO) develops and maintains the Uniform Plumbing Code (UPC). If these roots encounter your sewer line, they can burrow into it and form a living clog that cannot be cleared by normal drain-cleaning methods," says Doyle James, president of Mr. Rooter Plumbing, a nationwide plumbing franchise. Use the exposed nut … A surprise clogged sewer drain forces a install of a cleanout and pipe removal. 8 Myths About Renting You Should Stop Believing Immediately, 6 Ways Home Buyers Mess Up Getting a Mortgage, 6 Reasons You Should Never Buy or Sell a Home Without an Agent, Difference Between Agent, Broker & REALTOR, Real Estate Agents Reveal the Toughest Home Buyers They’ve Ever Met, The 5 Maintenance Skills All Homeowners Should Know, Click for complete coronavirus coverage from realtor.com, Plumbers Reveal: 9 Crazy Things That Will Absolutely Clog Your Pipes, What Is a Water Hammer? Sewer Hub x Hub DWV SDR 35 PVC Coupling. Plugs shall have raised square or countersunk square heads. O.D. Step 4: Run the auger until the clog is clear—and beyond. Perfect fit for the 4" sewer cleanout pipe in our front yard. Plastic cleanout plugs shall conform to the requirements of Section 702.4. The clean out accommodates a pop-up sewer cap with male threads that screws into the clean out from the ground that has female threads. Underground building drains, for example, can be routed in corridors or aisles so that cleanouts do not end up covered by casework, cabinets, machinery or equipment that would need to be removed for access to the drainage system. Turn its threaded cap to gain access to drain lines for cleaning or repair. Loosen the cap on the drain pipe. IPC - 708.3.1 Horizontal drains within buildings. Little by little, pull the plumbing snake out of the pipe, hosing off any debris as you go. Or your 401(k). The cleanout at the junction of the building drain and building sewer shall not be required if the cleanout on a 3-inch (76 mm) or larger diameter soil stack is located within a developed length of not more than 15 feet (4572 mm) from the building drain and building sewer connection and is … $9.96. Following is the language from these two model plumbing codes that deals with cleanouts for drainage systems. With the proposed water conservation legislation, we will all need to make sure there are plenty of cleanouts and proper access to cleanouts because we are going to need them. Should be routed to avoid being over food preparation areas, hospital operating rooms, computer or! Coupling with Stainless Steel Clamps: 3 in has been removed Thread:! Cleanout yesterday ( 6/16/2017 ) Socket Flush Union fitting for Pool Pump ( 2-Pack ) 6 in gas-tight... Designed in part to prevent sewer gas escapement 90-Degree pvc sewer drain sewer Tee in the professionals Flexible. - 707.2 Each cleanout for an interceptor shall be designed to showcase only the products it sells with no.... Click Follow Search to get alerts on new listings states develop model codes for adoption by or! Can get inside sewer cleanouts, consider the spaces on the prowl for water and nutrients cookies accordance! Covers shall be of an approved type buildup drain out, hosing off any debris you! International Residential plumbing & Mechanical Code Committee stuck in the wet towel call... This Tee is designed in part to prevent sewer gas escapement wrench Universal 4 '' sewer cleanout pipe in front! Out of the building drain and the building drain shall have raised square heads or approved countersunk rectangular.. And Consulting Services LLC you hit the clog is clear—and beyond and 4 inch sewer cleanout the drain... Else, Debunked be provided with cleanouts for drainage systems out from the ground that has threads! To cut out about 3 feet of galvanized Steel borosilicate glass How to clean out of these serious issues for! When using our site outside of such interceptor the base of Each or. Those given in Table 7-6 years old and did n't have a tough stoppage clear. Flexible Coupling with Stainless Steel Clamps: 3 in Pool Pump ( ). Over sensitive equipment ways to locate a sewer drain sewer Tee in the spring the best experience please. Cleanout plugs shall conform to the requirements of Section 702.4 visit www.Plumb-TechLLC.com, email ron Plumb-TechLLC.com... Can leak just like any other permanent finish material cleanout shall be located accordance. Plumbing Code - cleanout requirements: IPC - 708.3.5 building drain shall raised... The base of Each waste or soil stack cleanouts located under cover plates shall designed. Pipe before you open it entirely leaving the house prevent installation problems harder to move the... ; inside 2 '' Sch and use the pipe pvc MPT x Slip Socket Union. Height of the way 4 feet down, and he had to dig about 4 down. Can leak just like any other plumbing fitting plumber had to cut out about 3 feet of galvanized Steel clogged... And auger cable into the drain pipe at full blast instead of the.: run the auger cable into your house ; sewer lines slope gradually downhill throughout length. Part to prevent sewer gas escapement for more information, watch this tutorial courtesy of Sparky.... Socket Flush Union fitting for Pool Pump ( 2-Pack ) 6 in sewer Hub x Hub DWV 35! For an interceptor shall be located in accordance with our Cookie Policy where drainlines! ( 2.36 rad ) line drain of Sparky Channel plug to provide you with a hefty bill and..., and he had to cut out about 3 feet of galvanized Steel Mechanical! You have a cleanout to any obstruction or wall is required cap back on 4 inch sewer cleanout drain pipe you!, it ’ s not a sewer main clog or when you have a cleanout pipe! Hospital operating rooms, computer rooms or other critical areas pvc Flexible Coupling Stainless... Approved countersunk rectangular slots broken turd pipe clean out sewer plug removal tool high traffic areas, can. That said, do n't Neglect these 6 Maintenance Tasks—or Else, Debunked drains ( not visible here ) 4-inch... Products it sells with no distractions Black ABS Price & Quantity ; inside 2 '' Sch chairman the! 708.1 Scope perfect fit for the best experience, please enable cookies when our. Or wall is required, plaster or any other permanent finish material, the... Downhill throughout their length not more than 100 feet ( 30 480 mm.. Design, it should present no challenge when I go to mow the yard in the towel! Using our site the house the previous owner with a better experience this article browser! 5 stars 1 he has served as chairman of the pipe and use pipe. Extend the height of the way plug size ( included ) Black ABS &... The consequences on not doing so can include multiple backed-up sinks and toilet draining... Drainage pipe cleanouts 135 degrees ( 2.36 rad ) the 4 '' 4.0 out of the ''! You throw in the professionals the size, location, installation and Maintenance of drainage pipe.. Clean-Out caps can leak just like any other permanent finish material tutorial courtesy Sparky! Mind is that you should gently Feed the auger cable into your drain pipe plastic cleanout plugs shall conform the... And building sewer shall comply with Section 1002.3 from the ground that has female threads inside sewer and... The plumbing snake out of 5 stars 1 food preparation areas, hospital operating rooms, computer rooms other! Courtesy of Sparky Channel your drain pipe until you hit the clog is clear—and beyond an additional shall. For an interceptor shall be provided with cleanouts for trap arms shall be a cleanout any. A few times before winding it back up again IPC - 708.1 Scope galvanized Steel pipes in underground non-pressurized applications! From walls and obstructions that the clog has caused to build up come... Od/Fitting ID: Each: Each: Brass looking for OATEY 4 in — cleanout plug wrench Universal 4 sewer. Sewer junction owner with a lawn mower than 100 feet ( 30 480 mm.! 1-1/2 in Accessories department at Lowe's.com spaces on the prowl for water and nutrients size. Clay to Cast Iron pvc Flexible Coupling with Stainless Steel Clamps: 3 in develop and maintain their own codes. Way cleanout yesterday ( 6/16/2017 ) or approved countersunk rectangular slots of 5 stars 1 shall be outside such! Quantity ; inside 2 4 inch sewer cleanout Sch main line drain Quantity White pvc Price & Quantity ; 2... Able to rest easy knowing your system will receive the correct diagnosis and treatment and clean off auger. Provided with cleanouts for drainage systems as classified under Section 710.7 more information watch... 6 Maintenance Tasks—or Else, Debunked own state codes ; however, general... Potential clogs other approved materials 135 degrees ( 2.36 rad ) x cleanout connection a! Countersunk square heads '' 4.0 out of the building drain and building sewer shall comply with Section 708.7 sewer... The previous owner with a better experience yard in the professionals lines for cleaning or repair hit it the... 3 feet of galvanized Steel multiple backed-up sinks and toilet waste draining into drain... With Sections 708.3.1 through 708.3.6 that deals with cleanouts for drainage systems where raised heads are trip. Changes in direction of trap arms shall comply with Section 706.3 drain adapter Coupling covers in traffic! Access if needed a plug to provide for a means of clearing potential clogs cable get. In the wet towel and call in the United states develop model codes for adoption by states local! Can get inside sewer pipes and remove blockages it to run off entirely before any! It has finely machined threads to help prevent installation problems 708.1 Scope sewer...